• Image 1
  • Image 2
  • Image 3
  • Image 4
  • Image 5
  • Image 6

4000W Wind Solar Hybrid Charge Controller, 12V 24V 48V AUTO Match, MPPT Charge for Solar Panel Wind Turbine, for Lithium Lead A

From R4709.04
  • Color:

  • Current:

  • Rated Voltage:

200 in stock

Categories:
  • Description

    4000W Wind Solar Hybrid Charge Controller, 12V 24V 48V AUTO Match, MPPT Charge for Solar Panel Wind Turbine, for Lithium Lead A

    Product Description:

    This type controller is 12/24/48V system voltage automatically reorganize, the system voltage depends on your battery bank, for example, if your battery bank is 24V, then your the system voltage is 24V, in the same way, DC load Rated Voltage is 24V.

    Below is the matching recommendation for these different system voltage:

    12V battery bank: 12V wind generator + 18V Vmp solar panel array

    24V battery bank: 24V wind generator + 36V Vmp solar panel array

    48V battery bank: 48V wind generator + 72V Vmp solar panel array

    Below is clarification for hybrid controller model:

    eg. 3000W1515

    means 1500W Wind + 1500W Solar

    means The system can support Max 1500W wind generator and 1500W solar panel array.

    If you need the latest parameter sheet, please share us your email, we will sent to you.

    *Note1:For our Deluxe version hybrid controller,The default is lead-acid battery, you can enter the Bat-T-N battery type setting interface to change it.

    *Note2: For our Deluxe version hybrid controller, we have two system voltage version, 12/24V or 12/24/48V automatically reorganization*.

    Product Highlights.

    The controller adopts color screen design, the display information is more comprehensive, the display interface is clearer, the controller supports WIFI module and GPRS module to expand and implement APP cloud monitoring (optional).

    Product Application.

    The controller is suitable for wind solar off-grid system, automatically controls charging and discharging, and can be applied in communication base stations, household systems, street lighting systems, monitoring and other fields.

    Product Features.

    (1) The display adoptscolor screen design, the display information is more comprehensive, the display interface is clearer, and the 4-key man-machine interface and operation setting are more convenient;
    (2) The MPPTcontrol algorithm used for Wind charging ensures MPPT charging at low wind speed;
    (3) Wind three-stage charging mode: MPPT charging; lifting charging; floating charging.
    (4) Solar three-stage charging mode: CC (constant current); lifting charging; floating charging.
    (5) 12V/24V
     battery system automatically recognizes, or 12V/24V/48V battery system automatically recognizes (Optional).
    (6)
     RS485 communicationcan provide communication protocol to facilitate unified management and secondary development for customer;
    (7) The controller operating parameters can be viewed and set through the
    mobile phone APP( Optional );
    (8) The controller has
     comprehensive protection functionssuch as overcharge, over discharge and overload;
    (9)
     Four battery types charging modec an be selected for operation: Lead-acid battery, Ternary lithium battery, Lithium iron phosphate, Custom ;
    (10) The controller has various load control modes, the load has two outputs, and the output power and time can be set;
    (11) The controller has wide adaptability, adaptive day and night.

    Product Parameter:

    1. System Parameter

    Model

    2000W1010

    24000W1212

    2700W1215

    3000W1515

    3200W1220(Custom)

    3500W1520 (Custom)

    4000W2020  (Custom )

    System Rated Voltage

    12V(9V-16VDC)  /  24V(18V-32VDC)  /  48V(42V-60VDC)

    Solar Module

    Voc

    27.6V(12V)  /   55.2V(24V)  /   105V(48V)

    Vmp

    >Vbat+1V

    Imp

    Power ÷ Rated Voltage +1A (eg:1500W Solar Module ÷  48V( Rated Voltage)=32A)

    Workable Power

    0W~1000W

    0W~1200W

    0W~1200W

    0W~1500W

    0W~1200W

    0W~1500W

    0W~2000W

    Wind Turbine

    Rated Voltage

    12VAC(20.8VDC)/  24VAC (41.6VDC)/  48VAC(83.1VDC)

    Rated Current

    Power ÷ Rated Voltage +1A (eg:1500W Solar Module ÷  48V( Rated Voltage)=32A)

    Workable Power

    0W~1000W

    0W~1200W

    0W~1500W

    0W~1500W

    0W~2000W

    0W~2000W

    0W~2000W

    Max Open circuit voltage

    25.6VAC(12VAC)  /  51.2V(24VAC)  /  102.4V(48VAC)

    Special Note: The following are the optimal parameter settings, Suggest do not modify

    Uunder

    Over Discharge Voltage

    10.8V  /  21.6V  /  43.2V

    Runder

    Over Discharge Return

    13.1V  /  26.2V  /  52.4V

    Uover

    Over Charge Voltage

    15.5V  /  31.0V  /  62.0V

    Rover

    Over Charge Return

    15.0V   /  30.0V  /  60.0V

    BCV

    Increase Charge

    14.4V  /  28.8V  /  57.6V

    Float

    Floating Charge

    13.8V  /  27.6V  /  55.2V

    Ufanbraking

    Wind Breaking Voltage

    25.6V  /  51.2V  /  102.4V

    DC Load

    Out Power

    0W~180W
    (Per one-way)

    0W~700W
    (Per one-way)

    0W~1400W
    (Per one-way)

    Rated Voltage

    12VDC

    24VDC

    48VDC

    Current Max

    30A(15A*2)

    60A(30A*2)

    60A(30A*2)

    Conversion Efficiency

    ﹥98%

    Operation Mode

    Default to streetlight mode

    Environment

    Temperature

    1) Working:-20℃~50℃; 2)Storage:-30℃~70℃

    Humidity (°C)

    10% ~ 90% No condensation

    Protection Grade

    IP30

    Remark: This model supports one-key restore. Operation step: on the main interface of controller’s LCD display, first press the ESC key, then press the DOWN key, and finally press the ESC key again.

    Battery parameter reference table:

    Lead acid battery (single 12V)

    System rated voltage / V

    12V system (1 string)

    24V system (2 strings)

    48V system (4 strings)

    12V default value

    Overvoltage (overcharge) / V

    13~17V

    26~34V

    52~68V

    15.5V

    Overvoltage return / V

    13~17V

    26~34V

    52~68V

    15V

    Increase charging voltage / V

    9~15V

    18~30V

    36~60V

    14.4V

    Floating charge voltage / V

    9~15V

    18~30V

    36~60V

    13.8V

    Undervoltage /V

    7~13V

    14~26V

    28~52V

    10.8V

    Undervoltage return voltage /V

    9~15V

    18~30V

    36~60V

    13.1V

    Ternary lithium battery (single section 3.7V)

    System rated voltage

    12V system (default 3 strings)

    24V system (default 6 strings)

    48V system (default 12 strings)

    3 string defaults

    Overvoltage (overcharge) / V

    10.5~15V

    21~30V

    42~60V

    13.5V

    Overvoltage return / V

    10.5~15V

    21~30V

    42~60V

    12.6V

    Increase charging voltage / V

    10.5~15V

    21~30V

    42~60V

    12.4V

    Floating charge voltage / V

    6~13.5V

    12~27V

    24~54V

    12.0V

    Undervoltage /V

    6~13.5V

    12~27V

    24~54V

    9.3V

    Undervoltage return voltage /V

    6~13.5V

    12~27V

    24~54V

    10.5V

    Number of strings

    3~4

    6~8

    14~18

    3

    Lithium iron phosphate (single section 3.2V)

    System rated voltage

    12V system (default 3 strings)

    24V system (default 6 strings)

    48V system (default 12 strings)

    3 string defaults

    Overvoltage (overcharge) / V

    9~12V

    18~24V

    36~48V

    11.7V

    Overvoltage return / V

    9~12V

    18~24V

    36~48V

    11.1V

    Increase charging voltage / V

    9~12V

    18~24V

    36~48V

    10.8V

    Floating charge voltage / V

    9~12V

    18~24V

    36~48V

    10.2V

    Undervoltage /V

    6~12V

    12~24V

    24~48V

    8.4V

    Undervoltage return voltage /V

    6~12V

    12~24V

    24~48V

    9.6V

    Number of strings

    3~4

    6~8

    14~18

    3

    Details Images:

    Product Features:

    Note:Monitoring background supports WIFI module and GPRS module expansion to achieve APP cloud monitoring (optional), see APP operation manual for details; The controller defaults to lead-acid batteries. If you need to connect the other types of batteries, you need to set the corresponding battery type and series number. For details, please refer to the relevant settings of the APP manual.

    How to use?

    Large Size Screen Design

    Screen for 1000W Solar Panel and 1000W Wind generator

    Screen for 1200W Solar Panel and 1200W Wind generator

    Screen for 1500W Solar Panel and 1500W Wind generator

    Note: to know about more instruction and model, please contact us for FREE beautifully illustrated user manual(with various hybrid contoller product catalogue)

    list of items:

    FAQ

    1.Why choose MARS ENERGY as a provider of products?

    (1) Mars Energy is famous brand on the world market in new energy business. We have strong R&D technical teams and professional production lines;

    (2) Mars Energy is a manufacturer specializing in the production of controller from China. It has a complete quality management system and cost control advantages;

    (3) Mars Energy is a leader in cross-border e-commerce. After many years of operation, Mars Energy has completed the integration,Cooperate with world-renowned express logistics. Local delivery can be done quickly;

    (4) Mars Energy has established sales and after-sales teams in several countries, which can provide pre-sales guidance and after-sales service in a local language;

    (5) Since becoming a golden member of AL ABABA in 2005, Mars Energy has won praises from more and more customers around the world for its professionalism, responsible attitude and high quality.

     
     

    2.How to connect these 3 terminals of controller with my wind output wires?

    (1) To AC wind turbine, any one of three wires from wind turbine can be connected with any terminal of wind on your controller. For they are non-electrode;

    (2) To DC wind output is 2 wires(Positive Negative) , you can connect them with any wind terminals on your controller.

    3.How many connecting ways user can choose when using this controller?

    For the wind charging and Solar charging are independent, so user can choose any one of the following as the connection method :

    (1) Only connect wind turbine generator to charge battery;

    (2) Only connect solar to charge battery;

    (3) Connect wind turbine and solar to build a hybrid wind solar power system to charge battery.

    4.Can i only connect wind turbine as generator to charge battery when i get my controller?

    Yes, you can to do so. But for the main purpose of such controller designs for low power consumption equipment charging, such as: street lights and monitoring etc. So establish hybrid wind solar system can get better charging guarantee. Because most of low-power wind turbine is installed in or close to the residential place, wind generation efficiency is not high due to the low wind speed and short working time.

    5.How to connect my system when I get this controller?

    We strongly recommend user to install air switch between all DC and AC input or output. Then please turn on the breaker/ air switch in this order:

    (1) First turn on the breaker between battery and controller;

    (2) Second turn on the breaker between wind and controller;

    (3) Third turn on the breaker between DC load and controller;

    (4) Final turn on the breaker between Solar and controller.

    Remark: If you want to shut down the system, please proceed in the reverse order as above.

    6.Do i need to install additional light protecting for my power system?

    Yes, it is best way to install additional light protecting.

    7.How the controller to operate when the wind speed is too fast?

    (1) For the output voltage or current from wind generator which beyond the safety range, the controller will automatically turn on the brake and gradually slow down. Meanwhile, the dump load will start to consume excess current immediately.

    (2) But when encountering strong storm weather, such as hurricane, typhoon, it is strongly recommended to put down the wind turbine immediately.

    8.How to design hybrid wind solar power system voltage, 12V, 24V, 48V, which one is best to me?

    (1) The system voltage is equivalent to the voltage of the battery pack;

    (2) Once the battery voltage designed, the input voltage from wind turbine generator and solar modules must be matched according to the specifications in the parameter table;

    (3) Therefore, users cannot simply think that more lower voltage design, can get more bigger charging current but ignore that the excessive current has exceeded the working range of the controller or battery to damage the controller or battery.

    9.Why designed in MPPT?

    (1) Wind turbine charging adopted booster MPPT technology, which makes under low wind speed, the Wind turbine’s electricity can still be used;

    10.When the wind generator is connected to the controller, why its running speed becomes very slow immediately?

    (1) The battery reaches the floating voltage;

    (2) The rated output voltage of the wind generator is much higher than the battery, because the speed of the wind generator is proportional to the output voltage, and the voltage is dragged by the battery, so the speed will be very low;

    11.Why wind generator dump load when the controller displays small current?

    The controller protect the all system by detecting battery voltage, charging current and temperature and so on. When the battery reach floating charge voltage or high temperature, the wind generator will dump load, no matter how much charging current it is.

    12.Why there showing no charging current on LCD screen but the wind is running or the solar is working?

    Only when the input voltage Reach MPPT startup voltage (8V/16V/32V)then it can charge.But the prerequisite is that the battery is properly connected and not fully charged.

     

Follow us on:

Subscribe to our Newsletter
Please wait...