• Image 1
  • Image 2
  • Image 3
  • Image 4
  • Image 5
  • Image 6

5000W Wind Solar Hybrid System MPPT Charge Controller With Dump Load 2500w Wind Turbine2500W Solar Panel 12V 24V 48V Regulator

From R4484.79
  • Voltage:

  • Color:

  • Wattage:

200 in stock

Categories:
  • Description

    5000W Wind Solar Hybrid System MPPT Charge Controller With Dump Load 2500w Wind Turbine2500W Solar Panel 12V 24V 48V Regulator

    Product Description:

    Product Introduction

    This model is special designed for hybrid wind solar power system charge. system. And it is workable for Lithium , GEL, Lead-acid battery with full charge and discharge protection. Large size LCD screen is convenient for parameter(from solar, wind and battery) query and adjustment but low power consumption. It can be flexibly installed in cruise ships, RVs, and land indoors. Powerful functions and light size but very good heat dissipation are its outstanding features.
    Perfect Protection
    Solar Reversed Charging protection,Battery open circuit protection、battery anti-reverse connection protection protection、Over current and over voltage auto brake protection、Over load protection,etc.
     High performance and stable chip control;
     Automatically match with 12V/24V sealed battery voltage;
     Workable for battery: 1. Sealed( Lead-acid, GEL); 2. Lithium(Ternary Lithium, Lithium iron);
     LCD displays voltage and current of wind, solar and load parameter;
     The inner circuit board of the controller is sprayed to prevent dust, moisture and static electricity.
     Wind adopts MPPT boost charging; external dump-load resistance, intelligent disconnection of Solar charging.

    Product Parameter:

    1. System Parameter

    Model

    1600W0808

    2000W1010

    2400W1212

    2700W1512

    3000W1515

    3500W2015

    4000W2020

    4500W2520

    5000W2525

    System Rated Voltage

    12V/24V(Auto)  or  24V/48V(Auto)——Regular model

    12V/24V(Auto) or 24/48V(Auto)-Customized model

    Wind Turbine

    Rated Voltage

    12VAC / 24VAC / 48VAC

    12VAC  /  24VAC  /  48VAC

    MPPT(Boost Up)

    7VAC(12V System ) / 17VAC(24V System ) / 34VAC(48V System)

    Max Current

    45A(12V)34A  (24V)   17A  (48V)

    55A(12V)42A  (24V)   21A  (48V)

    66A(12V)50A  (24V)   25A  (48V)

    83A(12V)63A  (24V)   32A  (48V)

    83A(12V)

    63A (24V)

    32A  (48V)

    100A(12V)   83A  (24V)      42A  (48V)

     100A(12V)  83A   (24V)      42A   (48V)

    138A(12V)   104A   (24V)      52A     (48V)

     138A(12V)    104A   (24V)     52A   (48V)

    Workable Power

    0~800W

    0~1000W

    0~1200W

    0~1500W

    0~1500W

    0~2000W

    0~2000W

    0~2500W

    0~2500W

    Brake

    Start Voltage

    15VAC(21VDC) / 30VAC(42VDC) / 60VAC(48VDC)

    Recover Voltage

    13.5VAC(12V System ) / 27VAC(24V System ) / 54VAC(48V System )

    Solar Module

    Voc

    24V~27.6VDC(12V System) / 36V~55.2VDC(24V System) / 72V~105VDC(48V System)

    Vmp

    15V~22VDC(12V System) / 30V~44VDC(24V System) / 60V~88VDC(48V System)

    Charge Current(MAX)

    45A(12V)34A  (24V)   17A  (48V)

    55A(12V)42A  (24V)   21A  (48V)

    66A(12V)50A  (24V)   25A  (48V)

    66A(12V)50A  (24V)   25A  (48V)

    83A(12V)63A  (24V)   32A  (48V)

    83A(12V)   63A  (24V)       32A  (48V)

    100A(12V)   83A  (24V)       42A  (48V)

    100A(12V)   83A  (24V)       42A  (48V)

    138A(12V)   104A  (24V)      52A  (48V)

    Workable Power

    0~800W

    0~1000W

    0~1200W

    0~1200W

    0~1500W

    0~1500W

    0~2000W

    0~2000W

    0~2500W

    DC Load

    Out Put Power

    0~120W(12V System) / 0~240W(24V System) / 0~480W(48V System)

    Rated Voltage

    12VDC / 24VDC / 48VDC

    Max Current

    10A

    Environment

    Temperature

    1) Working:-20℃~55℃; 2)Storage:-40℃~80℃

    Humidity (°C)

    10%~90% No condensation

    Protection Grade

    IP30

    Others

    Conversion Efficiency

    ﹥98%

    Operation Mode

    Default to streetlight mode

    Packing Size

    Product size:171*145*69mm/PK Size: 200*350*120mm

    2. Battery Parameter

    System Voltage

    12V

    24V

    48V

    (b0)Customer Type

    FULL

    Over Charge

    14.7V

    Adjustable

    29.4V

    Adjustable

    58.8V

    Adjustable

    LOW

    Over Discharge

    10.2V

    Adjustable

    20.4V

    Adjustable

    40.8V

    Adjustable

    RLOW

    Over Discharge Return

    11.5V

    Adjustable

    23.0V

    Adjustable

    46.0V

    Adjustable

    Special Note: No one-key restore function, please do not modify preset parameters.

    (b1)Lead acid battery

    FULL

    Over Charge

    14.4V

    Default

    28.8V

    Default

    57.6V

    Default

    LOW

    Over Discharge

    10.2V

    Default

    20.4V

    Default

    40.8V

    Default

    RLOW

    Over Discharge Return

    11.5V

    Default

    23.0V

    Default

    46.0V

    Default

    (b2)Ternary lithium battery

    FULL

    Over Charge

    12.6V

    Default

    25.2V

    Default

    50.4V

    Default

    LOW

    Over Discharge

    9.0V

    Default

    18.0V

    Default

    36.0V

    Default

    RLOW

    Over Discharge Return

    11.0V

    Default

    22.0V

    Default

    44.0V

    Default

    (b3)Lithium Iron Phosphate LiFePO4

    FULL

    Over Charge

    14.4V

    Default

    28.8V

    Default

    57.6V

    Default

    LOW

    Over Discharge

    10.0V

    Default

    20.0V

    Default

    40.0V

    Default

    RLOW

    Over Discharge Return

    11.0V

    Default

    22.0V

    Default

    44.0V

    Default

    Details Images:

    Note: to know about more instruction and model, please contact us for FREE beautifully illustrated user manual(with various hybrid contoller product catalogue)

    Product Application:

    FAQ

    1.Why choose MARS ENERGY as a provider of products?

    (1) Mars Energy is famous brand on the world market in new energy business. We have strong R&D technical teams and professional production lines;

    (2) Mars Energy is a manufacturer specializing in the production of controller from China. It has a complete quality management system and cost control advantages;

    (3) Mars Energy is a leader in cross-border e-commerce. After many years of operation, Mars Energy has completed the integration,Cooperate with world-renowned express logistics. Local delivery can be done quickly;

    (4) Mars Energy has established sales and after-sales teams in several countries, which can provide pre-sales guidance and after-sales service in a local language;

    (5) Since becoming a golden member of AL ABABA in 2005, Mars Energy has won praises from more and more customers around the world for its professionalism, responsible attitude and high quality.

    2.How to connect these 3 terminals of controller with my wind output wires?

    (1) To AC wind turbine, any one of three wires from wind turbine can be connected with any terminal of wind on your controller. For they are non-electrode;

    (2) To DC wind output is 2 wires(Positive Negative) , you can connect them with any wind terminals on your controller.

    3.How many connecting ways user can choose when using this controller?

    For the wind charging and Solar charging are independent, so user can choose any one of the following as the connection method :

    (1) Only connect wind turbine generator to charge battery;

    (2) Only connect solar to charge battery;

    (3) Connect wind turbine and solar to build a hybrid wind solar power system to charge battery.

    4.Can i only connect wind turbine as generator to charge battery when i get my controller?

    Yes, you can to do so. But for the main purpose of such controller designs for low power consumption equipment charging, such as: street lights and monitoring etc. So establish hybrid wind solar system can get better charging guarantee. Because most of low-power wind turbine is installed in or close to the residential place, wind generation efficiency is not high due to the low wind speed and short working time.

    5.How to connect my system when I get this controller?

    We strongly recommend user to install air switch between all DC and AC input or output. Then please turn on the breaker/ air switch in this order:

    (1) First turn on the breaker between battery and controller;

    (2) Second turn on the breaker between wind and controller;

    (3) Third turn on the breaker between DC load and controller;

    (4) Final turn on the breaker between Solar and controller.

    Remark: If you want to shut down the system, please proceed in the reverse order as above.

    6.Do i need to install additional light protecting for my power system?

    Yes, it is best way to install additional light protecting.

    7.How the controller to operate when the wind speed is too fast?

    (1) For the output voltage or current from wind generator which beyond the safety range, the controller will automatically turn on the brake and gradually slow down. Meanwhile, the dump load will start to consume excess current immediately.

    (2) But when encountering strong storm weather, such as hurricane, typhoon, it is strongly recommended to put down the wind turbine immediately.

    8.How to design hybrid wind solar power system voltage, 12V, 24V, 48V, which one is best to me?

    (1) The system voltage is equivalent to the voltage of the battery pack;

    (2) Once the battery voltage designed, the input voltage from wind turbine generator and solar modules must be matched according to the specifications in the parameter table;

    (3) Therefore, users cannot simply think that more lower voltage design, can get more bigger charging current but ignore that the excessive current has exceeded the working range of the controller or battery to damage the controller or battery.

    9.Why designed in MPPT?

    (1) Wind turbine charging adopted booster MPPT technology, which makes under low wind speed, the Wind turbine’s electricity can still be used;

    10.When the wind generator is connected to the controller, why its running speed becomes very slow immediately?

    (1) The battery reaches the floating voltage;

    (2) The rated output voltage of the wind generator is much higher than the battery, because the speed of the wind generator is proportional to the output voltage, and the voltage is dragged by the battery, so the speed will be very low;

    11.Why wind generator dump load when the controller displays small current?

    The controller protect the all system by detecting battery voltage, charging current and temperature and so on. When the battery reach floating charge voltage or high temperature, the wind generator will dump load, no matter how much charging current it is.

    12.Why there showing no charging current on LCD screen but the wind is running or the solar is working?

    Only when the input voltage Reach MPPT startup voltage (8V/16V/32V)then it can charge.But the prerequisite is that the battery is properly connected and not fully charged.

Follow us on:

Subscribe to our Newsletter
Please wait...