10200W 8200W On Grid Inverter 48V 230V Hybrid Solar Inverter Off Grid Pure Sine Wave Inverter with MPPT 160A 180A Charger
Features:
Rated Power:8.2KW/10.2KW
MPPT voltage range:90-450V
Maximum solar charging current: 160A/180A(10.2KW)
Maximum AC charging current:140A/160A(10.2KW)
Connectable battery type: Lead-acid/Lithium iron phosphate(LiFePO4)/colloid/lithium battery
Waveform:Pure Sine Wave
Communication Interface:RS232/Wifi
Nominal operating frequency:50/60Hz
EVO 10200W:Dual MPPT
Expro 8200W 10200W:One MPPT
FAQ:
Q:Whether it can be connected to the grid?
A:PV gives priority to power supply to the load, and extra to charge the battery, and more can be integrated into the grid (need to be based on local government policies)
Q: Is this a on grid-tied inverter? Can it be output to utility?
A: YES. It is a hybrid inverter that can be both off-grid and on-grid connected
Q: Is it possible to use PV, battery, grid supply at the same time?
A: YES. The default PV priority mode, when the PV input is insufficient, the battery and utility will be used.
Q: Can inverters be connected in series or parallel?
A: NO.
Q: Can the utility be used to power the inverter when there is no sun?
A: YES.
Q: How to choose the power of the inverter according to the household appliances?
A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter is at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.
Q: How many solar panels need to be connected?
A: In order to start the inverter normally, the voltage of the solar panel is recommended to be 300V-400V, The maximum does not exceed 500V.
Inverter Use Notice
1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.
Product Parameters:
Model
|
EX-Pro-7200
|
EX-Pro-8200
|
EX-Pro-10200
|
Maximum PV Input Power
|
8200W
|
8200W
|
10200W
|
Rated Output Power
|
7200W
|
8200W
|
10200W
|
Maximum Solar Charging Current
|
160A
|
160A
|
180A
|
GRID-TIE OPERATION
|
PV Input(DC)
|
Nominal DC Voltage/Maximum DC Voltage
|
360VDC/500VDC
|
Start-up Voltage/Initial Feeding Voltage
|
90VDC/120VDC
|
Maximum DC Voltage
|
500VDC
|
MPPT Voltage Range
|
90V-450VDC
|
Number of MPPT Trackers/Maximum Input Current
|
1/27A
|
Grid Output(AC)
|
Nominal Output Voltage
|
220/230/240VAC
|
Output Voltage Range
|
195-253VAC
|
Nominal Output Current
|
31.3A
|
35.6A
|
44.3A
|
Efficiency (Peak) Battery to INV.
|
94%
|
Power Factor
|
>0.99
|
Feed-in Grid Frequency Range
|
49-51±1Hz/59-61±1Hz
|
Two Load Output Power
|
Full Load
|
7200W
|
8200W
|
10200W
|
Maximum Main Load
|
7200W
|
8200W
|
10200W
|
Maximum Second Load(battery mode)(Only if the battery voltage is below 44V
|
2400W
|
2733W
|
3400W
|
Main Load Cut Off Voltage
|
44VDC
|
44VDC
|
44VDC
|
Main Load Return Voltage
|
48VDC
|
48VDC
|
48VDC
|
OFF-GRID OPERATION
|
AC Input
|
AC Start-up Voltage/Auto Restart Voltage
|
120-140VAC/180VAC
|
Acceptable Input Voltage Range
|
90-280VAC or 170-280VAC
|
Maximum AC Input Current
|
40A
|
40A
|
50A
|
Nominal Operating Frequency
|
50/60Hz
|
Surge Power
|
14400W
|
16400W
|
20400W
|
Battery Mode Output
|
Nominal Output Voltage
|
48VDC
|
48VDC
|
48VDC
|
Output Waveform
|
Pure sine wave
|
Efficiency (DC to AC)
|
94%
|
Battery & Charger
|
Nominal DC Voltage
|
48VDC
|
48VDC
|
48VDC
|
Maximum Solar Charging Current
|
160A
|
160A
|
180A
|
Maximum AC Charging Current
|
140A
|
140A
|
160A
|
PHYSICAL
|
Dimension, D x W x H (mm)
|
537*390*130mm
|
Net Weight (kgs)
|
14.2
|
14.2
|
14.5
|
Communication interface
|
WIFI
|
EVO 10200W:
Product Parameters:
Model
|
SCI-EVO-7200
|
SCI-EVO-10200
|
RATED POWER
|
7200W
|
10200W
|
Maximum PV Input Power
|
7500W
|
10800W
|
GRID-TIED OPERATION
|
PV INPUT (DC)
|
Nominal DC Voltage/Maximum DC Voltage
|
360VDC/500VDC
|
Start-up Voltage/Initial Feeding Voltage
|
90VDC/120VDC
|
MPPT DC Voltage Range
|
90-450VDC
|
Number of MPPT Trackers/Maximum Input Current
|
1/27A
|
2/18A
|
GRID OUTPUT (AC)
|
Nominal AC Output Voltage
|
220/230/240VAC
|
AC Output Voltage Range
|
195.5-253VAC
|
Nominal AC Output Current
|
31.3A
|
44.3A
|
Power Factor
|
>0.99
|
Feed-in Grid Frequency Range
|
49-51±1Hz / 59-61±1Hz
|
EFFICIENCY
|
Maximum Conversion Efficiency (Solar to AC)
|
98%
|
TWO LOADS OUTPUT POWER
|
Full Load
|
7200W
|
10200W
|
Maximum Main Load
|
7200W
|
10200W
|
Maximum Second Load (battery mode)(Only if the battery voltage is below 44V)
|
2400W
|
3400W
|
Main Load Cut Off Voltage
|
44VDC
|
44VDC
|
Main Load Return Voltage
|
48VDC
|
48VDC
|
OFF-GRID OPERATION
|
AC Start-up Voltage/Auto Restart Voltage
|
120-140VAC/180VAC
|
Acceptable AC Input Voltage Range
|
90-280VAC or 170-280VAC
|
Maximum AC Input Current
|
40A
|
50A
|
Nominal Operating Frequency
|
50/60Hz
|
Surge Power
|
14400W
|
20400W
|
BATTERY MODE OUTPUT (AC)
|
Nominal Output Voltage
|
220/230/240VAC
|
Output Waveform
|
Pure sine wave
|
Efficiency (DC to AC)
|
94%
|
BATTERY & CHARGER
|
Nominal DC Voltage
|
48VDC
|
48VDC
|
Maximum Charging Current(Solar to AC)
|
140A
|
160A
|
Maximum AC Charging Current
|
120A
|
160A
|
GENERAL
|
Dimension, D x W x H (mm)
|
500*390*130mm
|
530*390*130mm
|
Net Weight (kgs)
|
13.1kg
|
14.5kg
|
Communication interface
|
WIFI
|
Humidity
|
5% to 95% Relative Humidity (Non-condensing)
|
Operating Temperature
|
–10°C – 50°C
|
Storage Temperature
|
–15°C – 60°C
|

PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
INVERTER MODEL
|
7.2KW
|
8 2KW
|
10.2KW
|
Max. PV Array Open Circuit Voltage
|
500Vdc
|
PV Array MPPT Voltage Range
|
90Vdc~450Vdc
|
Take 250Wp PV module as an example. After considering above two parameters, the recommended module configurations are listed as below table.
Solar Panel Spec, (reference)
-250Wp
-Vmp: 30.1Vdc
-Imp: 8.3A
-Voc: 37.7Vdc
-Isc: 8.4A
-ceils:60
|
SOLAR INPUT
|
Q’ty of panels
|
Total input power
|
(Min in serial: 6 pcs, max. in serial: 13 pcs)
|
6 pcs in serial
|
6 pcs
|
1500W
|
8 pcs in serial
|
8 pcs
|
2000W
|
12 pcs in serial
|
12 pcs
|
3000W
|
13 pcs in serial
|
13 pcs
|
3250W
|
12 pieces in serial and 3 sets in parallel
|
36 pcs
|
8200W
|
10 pieces in serial and 4 sets in parallel
|
40 pcs
|
10200W
|
Please connect the circuit correctly according to the instructions, and install circuit breaker switches for each circuit.
About Us
Anern,has been dedicated in bringing clean energy to each country,and help people all around the world to enjoy the facility and convenience brought by clean energy.
12 years enperience in solar energy and led lighting industry.providing service to over 200 countries and areas globally.having developed over 3,000 solar energy projects worldwide.
Anern has successfully completed hundreds of mega government projects in the past 12 years
Anern is headquartered in guangzhou,which is one of the most important Chinese Central Cities.
In addition to headquarter in Guangzhou,Anern has also set up factories and offices in Shenzhen,Zhongshan and Zhejiang

Follow us on: