• Image 1
  • Image 2
  • Image 3
  • Image 4
  • Image 5
  • Image 6
  • Image 7
  • Image 8
  • Image 9

Solar Hybrid Inverter 8.2KW 10.2KW 8200W 10200W On/Off grid DC48V AC230V Built-in 160A Charge Controller Dual PV Max 500V Input

From R12886.58
  • Color:

  • Output Voltage:

  • Ships From:

0 in stock

Categories:
  • Description

     

    10200W 8200W On Grid Inverter 48V 230V Hybrid Solar Inverter Off Grid Pure Sine Wave Inverter with MPPT 160A 180A Charger

    Features:

    Rated Power:8.2KW/10.2KW

    MPPT voltage range:90-450V

    Maximum solar charging current: 160A/180A(10.2KW)

    Maximum AC charging current:140A/160A(10.2KW)

    Connectable battery type: Lead-acid/Lithium iron phosphate(LiFePO4)/colloid/lithium battery

    Waveform:Pure Sine Wave

    Communication Interface:RS232/Wifi

    Nominal operating frequency:50/60Hz

    EVO 10200W:Dual MPPT
    Expro 8200W 10200W:One MPPT

    FAQ:

    Q:Whether it can be connected to the grid?

    A:PV gives priority to power supply to the load, and extra to charge the battery, and more can be integrated into the grid (need to be based on local government policies)

    Q: Is this a on grid-tied inverter? Can it be output to utility?

    A: YES. It is a hybrid inverter that can be both off-grid and on-grid connected

    Q: Is it possible to use PV, battery, grid supply at the same time?

    A: YES. The default PV priority mode, when the PV input is insufficient, the battery and utility will be used.

    Q: Can inverters be connected in series or parallel?

    A: NO.

    Q: Can the utility be used to power the inverter when there is no sun?

    A: YES.

    Q: How to choose the power of the inverter according to the household appliances?

    A: If household appliances contain inductive load appliances, such as refrigerators, washing machines, air conditioners, etc., the power of the inverter is at least three times the total power of the inductive load appliances, otherwise the appliances may not be able to start.

    Q: How many solar panels need to be connected?

    A: In order to start the inverter normally, the voltage of the solar panel is recommended to be 300V-400V, The maximum does not exceed 500V.

     

    Inverter Use Notice
    1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
    2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
    3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
    4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.

    Product Parameters:

    Model

    EX-Pro-7200

    EX-Pro-8200

    EX-Pro-10200

    Maximum PV Input Power

    8200W

    8200W

    10200W

    Rated Output Power

    7200W

    8200W

    10200W

    Maximum Solar Charging Current

    160A

    160A

    180A

    GRID-TIE OPERATION

    PV Input(DC)

    Nominal DC Voltage/Maximum DC Voltage

    360VDC/500VDC

    Start-up Voltage/Initial Feeding Voltage

    90VDC/120VDC

    Maximum DC Voltage

    500VDC

    MPPT Voltage Range

    90V-450VDC

    Number of MPPT Trackers/Maximum Input Current

    1/27A

    Grid Output(AC)

    Nominal Output Voltage

    220/230/240VAC

    Output Voltage Range

    195-253VAC

    Nominal Output Current

    31.3A

    35.6A

    44.3A

    Efficiency (Peak) Battery to INV.

    94%

    Power Factor

    >0.99

    Feed-in Grid Frequency Range

    49-51±1Hz/59-61±1Hz

    Two Load Output Power

    Full Load

    7200W

    8200W

    10200W

    Maximum Main Load

    7200W

    8200W

    10200W

    Maximum Second Load(battery mode)(Only if the battery voltage is below 44V

    2400W

    2733W

    3400W

    Main Load Cut Off Voltage

    44VDC

    44VDC

    44VDC

    Main Load Return Voltage

    48VDC

    48VDC

    48VDC

    OFF-GRID OPERATION

    AC Input

    AC Start-up Voltage/Auto Restart Voltage

    120-140VAC/180VAC

    Acceptable Input Voltage Range

    90-280VAC or 170-280VAC

    Maximum AC Input Current

    40A

    40A

    50A

    Nominal Operating Frequency

    50/60Hz

    Surge Power

    14400W

    16400W

    20400W

    Battery Mode Output

    Nominal Output Voltage

    48VDC

    48VDC

    48VDC

    Output Waveform

    Pure sine wave

    Efficiency (DC to AC)

    94%

    Battery & Charger

    Nominal DC Voltage

    48VDC

    48VDC

    48VDC

    Maximum Solar Charging Current

    160A

    160A

    180A

    Maximum AC Charging Current

    140A

    140A

    160A

    PHYSICAL

    Dimension, D x W x H (mm)

    537*390*130mm

    Net Weight (kgs)

    14.2

    14.2

    14.5

    Communication interface

    WIFI

     
     

    EVO 10200W:

    Product Parameters:

    Model

    SCI-EVO-7200

    SCI-EVO-10200

    RATED POWER

    7200W

    10200W

    Maximum PV Input Power

    7500W

    10800W

    GRID-TIED OPERATION

    PV INPUT (DC)

    Nominal DC Voltage/Maximum DC Voltage

    360VDC/500VDC

    Start-up Voltage/Initial Feeding Voltage

    90VDC/120VDC

    MPPT DC Voltage Range

    90-450VDC

    Number of MPPT Trackers/Maximum Input Current

    1/27A

    2/18A

    GRID OUTPUT (AC)

    Nominal AC Output Voltage

    220/230/240VAC

    AC Output Voltage Range

    195.5-253VAC

    Nominal AC Output Current

    31.3A

    44.3A

    Power Factor

    >0.99

    Feed-in Grid Frequency Range

    49-51±1Hz / 59-61±1Hz

    EFFICIENCY

    Maximum Conversion Efficiency (Solar to AC)

    98%

    TWO LOADS OUTPUT POWER

    Full Load

    7200W

    10200W

    Maximum Main Load

    7200W

    10200W

    Maximum Second Load (battery mode)(Only if the battery voltage is below 44V)

    2400W

    3400W

    Main Load Cut Off Voltage

    44VDC

    44VDC

    Main Load Return Voltage

    48VDC

    48VDC

    OFF-GRID OPERATION

    AC Start-up Voltage/Auto Restart Voltage

    120-140VAC/180VAC

    Acceptable AC Input Voltage Range

    90-280VAC or 170-280VAC

    Maximum AC Input Current

    40A

    50A

    Nominal Operating Frequency

    50/60Hz

    Surge Power

    14400W

    20400W

    BATTERY MODE OUTPUT (AC)

    Nominal Output Voltage

    220/230/240VAC

    Output Waveform

    Pure sine wave

    Efficiency (DC to AC)

    94%

    BATTERY & CHARGER

    Nominal DC Voltage

    48VDC

    48VDC

    Maximum Charging Current(Solar to AC)

    140A

    160A

    Maximum AC Charging Current

    120A

    160A

    GENERAL

    Dimension, D x W x H (mm)

    500*390*130mm

    530*390*130mm

    Net Weight (kgs)

    13.1kg

    14.5kg

    Communication interface

    WIFI

    Humidity

    5% to 95% Relative Humidity (Non-condensing)

    Operating Temperature

    –10°C – 50°C

    Storage Temperature

    –15°C – 60°C


    PV Module Selection:

    When selecting proper PV modules, please be sure to consider below parameters:

    1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.

    2. Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.

    INVERTER MODEL

    7.2KW

    8 2KW

    10.2KW

    Max. PV Array Open Circuit Voltage

    500Vdc

    PV Array MPPT Voltage Range

    90Vdc~450Vdc

    Take 250Wp PV module as an example. After considering above two parameters, the recommended module configurations are listed as below table.

    Solar Panel Spec, (reference)

    -250Wp

    -Vmp: 30.1Vdc

    -Imp: 8.3A

    -Voc: 37.7Vdc

    -Isc: 8.4A

    -ceils:60

    SOLAR INPUT

    Q’ty of panels

    Total input power

    (Min in serial: 6 pcs, max. in serial: 13 pcs)

    6 pcs in serial

    6 pcs

    1500W

    8 pcs in serial

    8 pcs

    2000W

    12 pcs in serial

    12 pcs

    3000W

    13 pcs in serial

    13 pcs

    3250W

    12 pieces in serial and 3 sets in parallel

    36 pcs

    8200W

    10 pieces in serial and 4 sets in parallel

    40 pcs

    10200W

    Please connect the circuit correctly according to the instructions, and install circuit breaker switches for each circuit.

    About Us

    Anern,has been dedicated in bringing clean energy to each country,and help people all around the world to enjoy the facility and convenience brought by clean energy.

    12 years enperience in solar energy and led lighting industry.providing service to over 200 countries and areas globally.having developed over 3,000 solar energy projects worldwide.

    Anern has successfully completed hundreds of mega government projects in the past 12 years

    Anern is headquartered in guangzhou,which is one of the most important Chinese Central Cities.

    In addition to headquarter in Guangzhou,Anern has also set up factories and offices in Shenzhen,Zhongshan and Zhejiang

Follow us on: